Why do motors still burn out in the era of variable frequency? How to avoid it?

2025-03-20 15:37:26來源:

With the widespread application of frequency conversion technology, motors have made significant progress in energy conservation, speed regulation, and automation control. However, many users have found that even with the use of a frequency converter, the motor may still burn out. What is the reason behind this? How can we effectively avoid it? This article will delve into the common causes of frequency conversion motor burnout and provide practical and feasible preventive measures.

138deaa250e23c9620be08aba368333a.jpg

1、Common causes of burnout of variable frequency motors

①. Low frequency operation leads to insufficient heat dissipation

When the variable frequency motor operates at low frequencies, the speed of its built-in fan will also decrease, resulting in a significant decrease in heat dissipation capacity. If the motor operates at low frequency for a long time, the internal temperature of the motor will gradually increase, ultimately leading to insulation aging or even burning.

②. Damage caused by harmonics and peak voltage

The PWM waves output by the frequency converter contain a large number of high-frequency harmonics, which can generate additional eddy current losses in the motor windings, leading to local overheating. In addition, the peak voltage (dv/dt) generated during the operation of the inverter switching components may break through the insulation and damage the acceleration motor.

③. Overload or improper parameter settings

If the motor runs in an overloaded state for a long time and the current exceeds the rated value, it will cause the winding to overheat. In addition, setting the acceleration/deceleration time of the frequency converter too short can cause instantaneous current surges and increase the burden on the motor.

④. Insulation aging and high-frequency environment

The high-frequency voltage output by the frequency converter will cause greater stress on the insulation material of the motor, especially in old motors or non frequency conversion dedicated motors, where the insulation aging rate will significantly accelerate.

⑤. Mechanical and Electrical Resonance

The frequency converter may cause mechanical resonance at certain frequencies, leading to bearing wear or winding looseness, which in turn can cause faults.

⑥. External environmental factors

If the operating environment of the motor is harsh (such as high temperature, humidity, and high dust), it will also accelerate the insulation aging and mechanical wear of the motor.

2、How to avoid the burning of variable frequency motors?

①. Choose a frequency conversion dedicated motor

The design of the frequency conversion dedicated motor has been optimized for high-frequency environments, with better insulation performance and heat dissipation capability. When selecting, giving priority to this type of motor can effectively reduce the risk of burning.

②. Optimize heat dissipation conditions

When operating at low frequencies, the self cooling ability of the motor decreases. It is recommended to install an independent cooling fan to forcibly dissipate heat. At the same time, ensure that the motor installation environment is well ventilated and avoid high-temperature operation.

③. Install protective devices

·Reactors and filters: Installing reactors or filters at the output of the frequency converter can effectively suppress harmonics and peak voltages, reducing damage to the motor.

·Dv/dt filter or sine wave filter: These devices can smooth the voltage waveform output by the frequency converter and reduce high-frequency damage.

④. Reasonably set the parameters of the frequency converter

·Acceleration/deceleration time: Set reasonable acceleration/deceleration time based on load characteristics to avoid instantaneous current surges.

·Carrier frequency: Adjust the carrier frequency to a reasonable range (such as 2-4kHz) to balance noise and heat generation issues.

·Minimum operating frequency: Control the minimum operating frequency of the motor to be ≥ 10Hz to ensure self cooling effect.

⑤. Regular maintenance and testing

·Insulation resistance testing: Measure the insulation resistance of the motor every quarter to ensure that the resistance value is greater than 1M Ω.

·Bearing and vibration testing: Regularly check the condition of bearings and motor vibration to avoid mechanical resonance or wear.

·Temperature monitoring: Install temperature sensors to monitor the motor's operating temperature in real-time and detect any abnormalities in a timely manner.

⑥. Avoid overloading operation

Ensure that the motor operates within the rated load range and avoid prolonged overload operation. If the load fluctuates greatly, it is recommended to choose a motor with higher power.

⑦. Improve the operating environment

Keep the operating environment of the motor clean, dry, and ventilated to avoid the impact of high temperature, humidity, and dust on the motor.

The reasons for the burnout of variable frequency motors are complex and diverse, but through scientific selection, reasonable parameter settings, comprehensive protection measures, and regular maintenance, the failure rate can be significantly reduced and the service life of the motor can be extended. In the era of frequency conversion, only by fully understanding the operating characteristics of the motor and taking targeted protective measures can the stable and efficient operation of the equipment be ensured.

Hengda Electric has always been dedicated to the research and development, production, and service of variable frequency motors. With advanced technology and equipment, lean manufacturing processes, reliable product quality, and satisfactory after-sales service, the company provides customers with the most suitable motor professional solutions and creates greater social value.

3dfa4e576a4b3418e554c0afd8631d29.jpg

国模裸体无码xxxx视频| 免费国产在线精品一区| 免费人成年小说在线观看| 色哟哟精品视频在线观看| 成人欧美一区二区三区黑人| 毛茸茸厕所偷窥xxxx| av无码久久久久久不卡网站 | 精品无码中文字幕在线| 热久久国产欧美一区二区精品| av无码精品一区二区三区| 欧洲美熟女乱又伦| 国产麻豆天美果冻无码视频 | 久久99精品久久久久久清纯| 亚洲最大国产成人综合网站| 美女裸体a级毛片| 国产极品久久久久极品| 日韩精品无码免费专区网站| 麻豆成人精品国产免费| 米奇7777狠狠狠狠视频影院| 亚洲精品美女久久久久99| 成人无码一区二区三区| 四虎影视久久久免费| 国产永久免费高清在线观看| 人人妻人人玩人人澡人人爽| 扒开双腿疯狂进出爽爽爽视频| 国模欢欢炮交啪啪150| 亚洲国产精品va在线看黑人| 日韩精品极品视频在线观看免费| 亚洲日韩精品一区二区三区无码 | 日韩放荡少妇无码视频| 色欲综合一区二区三区| 97久久久久人妻精品区一| 色偷偷偷在线视频播放| 国产精品久久国产精麻豆99网站| 亚洲中国精品精华液| 伊人久久大香线蕉av不变影院| 乱熟女高潮一区二区在线| 国产乱视频在线观看| 欧美熟妇xxxxx欧美老妇不卡| 国产精品久久久天天影视| 无人区乱码一区二区三区|